        About Spo2

        作者:山西潔瑞醫療器械股份有限公司 瀏覽: 發表時間:2019-08-01 14:24:24

        I. No Blood Oxygen,No luminescence

           

        1.Possible cause:Luminescent pipe was broken                                                      Solution:   contact manufacturer

         

        2.Possible cause:The luminous tube side cable short circuit                                  Solution:   contact manufacturer

         

        3.Possible cause:Machine-end connection is bad                                                    Solution:   Connect the ends of the machine

         

        4.Possible cause:incorrect polarity                                                                          Solution:   contact manufacturer

         

        5.Possible cause:The plug is too loose, could not receive the host signal           Solution:   contact manufacturer


        II. No Blood Oxygen and wavefor


        1.Possible cause:Receiver tube anomalies                                                            Solution:   contact manufacturer to repair

         

        2.Possible cause:unstable, luminescence, receiver tube circuit breaker               Solution:   contact manufacturer to repair

         

        3.Possible cause:incompatible                                                                              Solution: Choose the right compatible model

         

        4.Possible cause:Light-Leaking Seriously                                                            Solution:Re-use according to the instruction manual

         

        5.Possible cause:Probe selection error                                                                  Solution: According to the machine instructions to select the correct probe

         

        6.Possible cause: testing position there is no alignment LEDs and receiver        Solution:Re-use according to the instruction manual

         

        7.Possible cause:Patient Attention is too low try several measurements             Solution:Please go to the hospital for accurate diagnosis

         

        8.Possible cause:The fingers are trembling or the patient's body is moving        Solution:Don’t Move


        圖片展示
        公眾號

         

         

         

        圖片展示

        首頁      |      關于潔瑞   |    產品中心   |      新聞動態     |    服務中心    |      聯系我們      

        國內銷售:

        公司地址:山西省太原市高新區長治路303號大生科技701、702室

        電       話:0351-7036736 或 18636695252 王經理

        傳       真:0351-7036740

        電子郵箱:cnsales@sxjerrymed.com

         

        Copyright @ VillaGrandis All Rights Reserved  ICP備案號180006020號-3

        在線咨詢

        您好,請點擊在線客服進行在線溝通!

        聯系方式
        熱線電話
        +86-0351-7036736/737/738
        上班時間
        周一到周六上午
        郵箱
        sales@sxjerry.com
        掃一掃二維碼
        復制成功
        微信號:1234
        添加微信好友,詳細了解產品
        我知道了
        五月丁香缴情深爱五月天视频,日本亚洲欧美日韩国产AY,思思久99久女女精品视频,秋霞电影院午夜伦高清A片
        1. <table id="vnfzi"></table>
            <p id="vnfzi"></p>
          1. <td id="vnfzi"></td>

            <td id="vnfzi"></td>

            <tr id="vnfzi"></tr>
            <acronym id="vnfzi"></acronym><track id="vnfzi"></track>